Monacor IMG Stage Line AKB-60 60W Mono Amplifier
Part No.: 0320740
Description:
A compact, high-quality mono amplifier module consisting of a pre-amplifier, a power amplifier and a mains supply unit, suitable for hi-fi applications and for PA in small rooms. Its compact size and mounting brackets mean it can be fixed directly to a speaker cabinet, turning a passive speaker into an active one. Just mount the module on the rear of the speaker cabinet and connect its speaker cable to the speaker's input terminals. It is also very well suited as a measuring amplifier for acoustic analysers.
Key Features:
- Active Speaker Module: Mono amplifier delivering 45W RMS into 4 Ohm (60W maximum music power).
- Powers Passive Speakers: Convert a passive speaker to an active speaker system with a single module.
- Easy Mounting: Mounting brackets for fixing to the rear of a speaker cabinet, next to the speaker terminals.
- Balanced or Unbalanced Inputs: Line input via balanced XLR or unbalanced RCA.
- Adjustable Level: Front level control to set the output volume.
- Fanless Design: A fanless concept with a large heat sink, so it runs silently.
- Protection Circuit: Protected against short circuit and overheating.
- Illuminated Power Switch: Mains switch that lights up when the amplifier is on.
Typical Uses:
- Converting passive speakers into active speakers.
- Powering a speaker in a hi-fi system.
- Background music and small PA systems in small rooms.
- Use as a measuring amplifier with acoustic analysers.
- DIY audio projects that need a compact amplifier with its own power supply.
Specifications:
Output
- Output power: 1x 45W RMS into 4 Ohm
- Output power: 1x 30W RMS into 8 Ohm
- Maximum music power: 1x 60W into 4 Ohm
- Maximum music power: 1x 40W into 8 Ohm
- Load impedance: 4-8 Ohm
- THD: < 0.01%
- Frequency range: 15-50,000Hz (-3dB)
- S/N ratio: > 80dB
Input
- Input sensitivity: 0.4V (400mV)
- Input impedance: 20kOhm (XLR, balanced); 11kOhm (RCA, unbalanced)
- Inputs: 1x XLR (balanced); 1x RCA left / right
- When both RCA inputs are used, the signals are mixed to mono.
Connections and Controls
- Speaker output: Cable with red (+) and black (-) leads, for 4-8 Ohm speakers
- Level control: Yes
- Mains switch: Yes, illuminated
- Mains connection: IEC socket, with a mains cable supplied
- Fuse: Replaceable mains fuse, in a holder next to the mains socket
General
- Power supply: 230V AC / 50Hz, 90VA max.
- Operating temperature: 0°C to 40°C
- Dimensions (W x D x H): 212 x 190 x 52mm (approx.)
- Weight: Approx. 2.2kg
- For indoor use only
XLR Connection (balanced input):
- Pin 1: Ground
- Pin 2: Signal +
- Pin 3: Signal -
Mounting and Installation:
- Mounting: Fix the amplifier with its mounting brackets, for example to the rear of a speaker cabinet next to the terminals.
- Cooling: The amplifier is cooled by air flowing through the cooling fins on the rear and the vents in the case. Allow air to flow freely, never cover the vents, and do not mount it inside a closed enclosure.
- Signal Source: Connect a line level source, such as a CD player, mixer output or the line output of a computer, to the XLR input for balanced signals or the RCA inputs for unbalanced signals.
- Speaker: Connect the amplifier's speaker cable to a 4-8 Ohm speaker, red to positive and black to negative. If you connect more than one speaker, make sure the total impedance does not fall below 4 Ohm.
- Stereo: This is a mono amplifier, so for a stereo system use one amplifier per speaker.
- Power: Connect the mains cable to the IEC socket and plug it into a mains socket.
Operating Tips:
- Set the level control to minimum before you switch on.
- To avoid switching noise, switch the amplifier on after the connected equipment, and switch it off first after use.
- Do not turn the level up so far that the sound distorts.
- Avoid very high volumes, which can damage your hearing over time.
Safety Notes:
- This unit uses dangerous mains voltage. Do not open it or insert anything through the vents. Leave servicing to skilled personnel only.
- For indoor use only. Protect it from dripping water, splash water, high humidity and heat.
- Never cover the vents, and do not place anything holding liquid on the unit.
- If the unit or mains cable is visibly damaged, or the unit has been dropped, switch it off, unplug it and have it checked by a specialist.
- Only replace a blown fuse with one of the same type.
- Pull the mains plug, not the cable, to unplug it.
- Clean with a dry, soft cloth only.